• Jingtong Rubber Inflatable Airbag Water Stop Pipe Test Plug
  • Jingtong Rubber Inflatable Airbag Water Stop Pipe Test Plug
  • Jingtong Rubber Inflatable Airbag Water Stop Pipe Test Plug
  • Jingtong Rubber Inflatable Airbag Water Stop Pipe Test Plug
  • Jingtong Rubber Inflatable Airbag Water Stop Pipe Test Plug
  • Jingtong Rubber Inflatable Airbag Water Stop Pipe Test Plug

Jingtong Rubber Inflatable Airbag Water Stop Pipe Test Plug

Condition: New
Certification: ISO, CE
Pressure: 0.02MPa
Shape: Cylindrical
Material: Nr
Function: Waterproof
Samples:
US$ 1/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory

Basic Info.

Model NO.
JTSD-001
Color
Black
Thickness
3mm
Length
0.5m -50m
Payment
50% Deposit+50% Balance
Transport Package
in Roll on Pallet in Bag
Specification
dia50mm-2500mm
Trademark
JINGTONG
Origin
Hebei
HS Code
4008290000
Production Capacity
1000PCS/30days

Product Description

Rubber Pipe Plug
Rubber Pipe Plug (Duct pipeline occlude) is made by enhancing natural rubber, each pipe sealing bag before delivery, will be 1.5 times the rated working pressure and diameter corresponding model test conditions. In order to ensure the strength of the pipe sealing balloon structure, we use a safety factor to the tube three times the rated working pressure seal. Pipeline shutoff balloon by balloon, pressure gauge, three, six meters long special pneumatic hose, pump components. Floors in the building closed water tests can withstand 2-6 storey natural water pressure. 
Duct sealing bag suitable for sealing all kinds of cast iron repair pipes, glass pipes, PVC pipes, PPR pipes, double-wall spiral pipe, etc., maintenance side leakage. The pipe sealing balloon compared with other pipe sealing bag, light weight, easy to carry, easy to operate, features simple construction.
Jingtong Rubber Inflatable Airbag Water Stop Pipe Test Plug
Jingtong Rubber Inflatable Airbag Water Stop Pipe Test Plug


Rubber balloon plugging Usage:
1> Preparation: connect all parts rubber plug accessories.
2> Open pipeline checking outlet, put rubber plug down slowly, and then aerated rubber plug up to right pressure.    Tip: avoid raiser member joints.
3> Rubber plug joint &hose interface should be tied or fastened with wire avoiding unglued
4> Inject water into building checking outlet up to level of building deck, and then checking pipeline and fittings. If find leaks, mark them and fix them after draining. If no leaks, the water level should be stable. Irrigation continuation15 minutes, it is qualified if the water level does not drop holding for 5 minutes
5> Deflate the rubber plug, pull plug out of pipeline, keep plug not damaged. Water flow away after taking out plug, If water level reduce slowly, pipeline clogged, need clear up
6> Rubber plug also can checking whether Squat toilet leaks. Put rubber plug in drain outlet and aerated, Irrigation to squat toilet, if water level reduces, it comes out leaks somewhere, or not strict closure.
7> Water testing should conduct by stratified and make record.
8> Rubber plug is pipe plugging, Closed water and gas test, be professional products used in building pipe plugging.
 
Jingtong Rubber Inflatable Airbag Water Stop Pipe Test Plug
Jingtong Rubber Inflatable Airbag Water Stop Pipe Test Plug


Pipeline Plug Specifications:
Type Pipeline Dia(mm) Airbag
Dia (mm)
Length
(mm)
Pressure
(Mpa)
Withstand water pressure Weight 1(Kg) Weight 2(Kg) Weight 3(Kg)
JT50-A 50 51 135
Inflatable tube
Under 5m
Hydrostatic
0.079 - -
JT75-A 75 77 160 0.15 - -
JT100-A 100 105 210 0.33 - -
JT150-A 150 155 280 0.62 - -
JT200-A 200 205 310 1.1 - -
JT300-A 300 305 1000 0.045 3.85 4.3 4.95
JT400-A 400 405 1000 0.04 5.36 6.13 6.90
JT500-B 500 505 1000 0.035 6.87 7.85 8.84
JT600-B 600 605 1000 0.028 8.58 9.80 11.10
JT700-B 700 710 1000 0.027 10.39 11.88 13.36
JT800-B 800 810 1200 0.025 14.2 16.3 18.5
JT900B 900 910 1350 0.02 18.1 20.7 23.3
JT1000-B 1000 1010 1500 0.02 - 26.5 29.4
JT1200-B 1200 1210 1800 0.02 - 36.8 42.3
JT1500-B 1500 1510 2250 0.015 - - 65.5
JT1800 1800 1810 2500 0.015 - - 88.8
JT2400 2400 2410 3500 0.015 - - 161.5
Rubber balloon plugging working principle
Be to use high-quality rubber pipe sealing bag made by a pneumatic method to inflate, when the gas pressure inside the balloon plugging meet the requirements, the water shut off airbag fill the pipeline section, the use of pipe sealing balloon wall and pipe friction generated by plug leaks, so as to achieve the target pipe without seepage purposes.

Jingtong Rubber Inflatable Airbag Water Stop Pipe Test Plug
Certification
Jingtong Rubber Inflatable Airbag Water Stop Pipe Test Plug
Jingtong Rubber Inflatable Airbag Water Stop Pipe Test Plug
Jingtong Rubber Inflatable Airbag Water Stop Pipe Test Plug
Packing
                                       In bag                                                                           In carton

 
Jingtong Rubber Inflatable Airbag Water Stop Pipe Test Plug
Jingtong Rubber Inflatable Airbag Water Stop Pipe Test Plug

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now